Rangemaster RG60 Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
13
8. Technical Data
The hob is an independent Class 3 built-in unit.
This hob is category II
2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Base of the hob.
COUNTRY OF DESTINATION: GB/IE
Gas Electric
Natural Gas 20mbar 220 240V 50Hz
Butane 29mbar
Propane 37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
Above worktop 50mm Below worktop 50mm
Overall width
620mm; see Positioning of Cooker
Overall depth
520mm
Space for fixing
See ‘Positioning of Cooker
Minimum space above hotplate
650mm
Connections
Gas Electric
Rp ½ at rear right-hand side 220 240V 50Hz
Ratings
Natural Gas L.P. Gas
Hotplate
Injector Injector
Large Burners 3.0kW 129 3.0kW (218g/h) 87
Medium Burners 1.75kW 101 1.75kW (124g/h) 66
Small Burner 1.0kW 77 1.0kW (73g/h) 50
Gas burner inputs based on Gross Calorific Value
DocNo.101-0001 - Technical data RG60 gas